On the environmental effects on a point discharger
No Thumbnail Available
Date
2011
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
The environmental effect on a point discharger has been investigated. It was found that the magnitude of point-discharge current (Ip) measured from a discharger is strongly affected by the presence of other dischargers, particularly when they are very close to the discharger through which Ip is measured. The starting potential depends on the tip clearance of the central discharger rather than the separation of the points. At higher tip clearances the compound discharger exhibits a stepped-leader like process. Atmospheric contaminants also affect the magnitude of Ip.
Description
Keywords
discharge current, starting potential, point discharger, tip clearance, environmental effect