ncessant Collapse of Buildings in Nigeria: The Possible Role of the Use of Inappropriate Cement Grade/Strength Class
Date
2014
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
The use of low quality concrete has been identified as
one of the main causes of the incessant collapse of buildings in
Nigeria. Emphasis has been on the use of poor quality aggregates,
poor workmanship and the use of lean concrete mix with low cement
quantity as the reasons for the low quality of concrete used for
building construction in Nigeria. Surveys conducted revealed that in
the construction of most privately owned buildings where concrete
trial mixes and concrete compressive strength quality assurance tests
are not conducted, concretes used for building constructions are
produced using the 1:2:4 mix ratio irrespective of the cement
grade/strength class. In this paper, the possible role of the use of
inappropriate cement grade/strength class as a cause of the incessant
collapse of building in Nigeria is investigated. Investigation revealed
that the compressive strengths of concrete cubes produced with
Portland-limestone cement grade 32.5 using 1:2:4 and 1:1.5:3 mix
ratios are less than the 25MPa and 30MPa cube strengths generally
recommended for building superstructures and foundations
respectively. Conversely, the compressive strengths of concrete cubes
produced with Portland-limestone cement grade 42.5 using 1:2:4 and
1:1.5:3 mix ratios exceed the 25MPa and 30MPa generally
recommended for building superstructures and foundations
respectively. Thus, it can be concluded that the use of inappropriate
cement grade (Portland-limestone cement grade 32.5), particularly
for the construction of building foundations is a potential cause of the
incessant collapse of buildings in Nigeria. It is recommended that the
Standards Organisation of Nigeria should embark on creating
awareness for Nigerians, particularly, the home owners and the
roadside craftsmen that Portland-limestone cement grade 32.5 should
not be used for the construction of building load-carrying members,
particularly, building foundations in order to reduce the incessant
incidence of collapsed building.